FACI SAF 26 semi-automatic boiler

🧮Calculate heating costs
pellets vs diesel, gas and electricity · boiler model selection
Convenient digital control panel
Automatic ignition
Complete fuel combustion
Unique design
EAC Declaration of Conformity
Specifications:
  • Output26 kW
  • Fuel typefirewood, coal, fuel briquettes
  • Boiler dimensions LxWxH, mm880x670x1320
  • Flue diameter159 mm
  • Weight215 kg
  • Useful output at 70 °C13 kW
Fuel types:
Choose a configuration:
The package includes:
No additional options
Price:
268 800 ₽
240 000 ₽
Get a commercial proposal

Boiler description:

FACI SAF is today's optimal solution to the heating problem:

  • both for owners of small premises from 100 m² who are used to heating with traditional fuels — firewood and coal;
  • and for large commercial and industrial facilities where cost-effectiveness is paramount and staff can be present in the boiler room from time to time.

FACI SAF — excellent value for money!

This boiler successfully combines:

1. The traditional functions of semi-automatic boilers we are all used to

But we have tried to make them a little more convenient for you, namely:

  • a huge loading chamber for fuel, so you have to attend to the boiler as rarely as possible;

  • a horizontal fire-tube heat exchangerlocated directly above the main combustion zone, so that the flue gases stay in the heat exchanger as long as possible and transfer the maximum amount of heat — thanks to this solution boiler efficiency reaches 85%.

2. Innovations by FACI engineers to increase automation and comfort

Now you have:

  • boiler output control depending on the outdoor weather, time of day or your preferences;
  • operation to a set temperature of the heat carrier;
  • air supply adjustment from the boiler control panel;
  • automatic overheat protection of the heat carrier.

3. And a stylish look from Italian industrial designers

FACI has always stood out for its unique, ergonomic, clean-lined design that makes you want to put it in the living room.
It is a pleasure to work with.

See for yourself — order a boiler by the end of December at a reduced price and forget about heating problems by the New Year!

Advantages of FACI SAF boilers:

Output control (fan control)

Simple, convenient and smooth control of boiler output with a rotary knob that adjusts the intensity of the air supply.

Controlling the boiler is now as easy as using a gas cooker.
The boiler control system is designed so that even a child can manage it. The boiler requires no commissioning by a specialist. You can easily control the boiler output with the knob that regulates the air supply to the furnace. This way you choose the mode yourself: full output to heat the room quickly, or simply maintaining the set temperature.

Automatic ignition

FACI SAF is equipped with a convenient automatic ignition function. The boiler ignites automatically (if it is not in operating mode) when the heat carrier temperature falls below the set value. This feature is handy in country houses at the start of the season.

Automatic ignition

For the first time for this type of boiler, an Auto-ignition option is available!

With the "Auto-ignition" function, the boiler starts automatically when the heat carrier temperature falls below the set value.
An excellent solution for country houses.

Now your boiler can light itself — say, early in the morning while you are asleep.

Complete fuel combustion

Thanks to its algorithms, the boiler's original automation ensures complete fuel combustion and an efficiency of up to 85%.


Certificates

Semi-automatic heating boilers simplify heating a house or other premises. The equipment has a microprocessor controller that regulates auxiliary processes: the speed of the built-in fans, maintaining a set temperature in the heating system, switching pumps on and off, and more. After solid fuel is loaded, the equipment switches to automatic mode. With firewood, autonomous operation can last up to eight hours; with coal, up to twelve hours.

How a semi-automatic combination boiler works

To start heating, firewood is loaded onto the grate and lit. Because there is not enough air in the combustion chamber, the wood chars and releases wood gas (pyrolysis). Part of the gas goes down under the grate, mixes with secondary air and enters the lower part of the fuel. The supply of air and gas keeps the pyrolysis process going. Semi-automatic solid fuel heating boilers based on pyrolysis are highly efficient and can run for a long time on a single load. Combustion produces very little ash, so the combustion chamber does not need constant cleaning. When choosing a heating system for a country house or cottage, consider the output of the equipment and the fuel used. We also recommend paying attention to the loading type: top or bottom loading.

Automated fuel loading

To eliminate "manual mode", the combustion process must be automated; it depends on the supply of fuel and oxidant and on the correct operation of the safety system. The main factor of automatic mode is timely fuel feed. The simplest option is an auger feed, which requires buying and installing a special unit that delivers fuel to the combustion chamber. The auger connects the long-burning wood boiler to the storage hopper. Once fitted, the equipment can operate automatically for several days, depending on the hopper volume. Automatic feed helps automate the process, reduces maintenance time and ensures economical fuel use. If no additional equipment is planned and there are few monitoring options, we recommend considering semi-automatic wood-fired heating boilers.

What operating modes are available

Complete combustion may require different amounts of air. For example, firewood needs less air than coal. If the same air supply mode is used for the combustion chamber, some fuels will burn too quickly and others will not burn out. Another function of the control unit is to switch off the blower fan in time when the set heating system temperature is exceeded. This saves electricity and prevents overconsumption. When the fan stops, air stops entering the combustion chamber and the fuel goes from active burning to smouldering. When the heating system reaches the minimum temperature (5 degrees), the fan switches on automatically and combustion restarts. Switching the fan on and off helps maintain the required heating system temperature. Temperature sensors, fans and a control unit make the multi-fuel heating boiler efficient and ensure long operation on a single load.

Advantages

The advantages of semi-automatic models include:
  1. Output control. The process is simple, convenient and smooth: just turn a knob that sets the intensity of the air supply. Operating the boiler is as easy as using a gas cooker. No commissioning is required before the first start. Note that running the unit at full output heats the room as quickly as possible but uses more fuel.
  2. Automatic ignition. Much like auto-ignition systems, the boilers can start automatically when the heat carrier cools down.
  3. Fuel burns 99.9%. This is thanks to the original automation algorithms that achieve 85% efficiency. 
  4. With coal, combustion lasts 50% longer;
  5.  Servicing and maintenance take 3-4 times less time than with a conventional boiler;
  6. Convenient automatic ignition. The boiler can ignite automatically when it is not in operating mode. The burner fires when the heat carrier temperature deviates from the set limit. Residents of country houses used all year round really appreciate this feature.
  7. Long burning and removable grates. Air passes through the grate and sustains even, long-lasting combustion in the centre of the boiler, more precisely under the heat exchanger. Removable grates are used for good reason: since they are not part of the heat exchanger, they can be replaced quickly and, most importantly, without a specialist or significant cost.
  8. Horizontal heat exchanger. This is a traditional solution for FACI boilers — a drum-type fire-tube design, the true signature of the unit.
  9. Special boiler configuration. It is designed so that flue gases pass repeatedly through the cylindrical heat exchanger made of high-quality stainless steel.